Effect of Use of a Bougie vs Endotracheal Tube With Stylet on Successful Intubation on the First Attempt Among Critically Ill Patients Undergoing Tracheal Intubation: A Randomized Clinical Trial.

Document Type

Article

Publication Date

12-28-2021

Publication Title

JAMA : the journal of the American Medical Association

Keywords

Adult; Aged; Critical Illness; Female; Humans; Intubation, Intratracheal; Male; Middle Aged; Oxygen Saturation

Abstract

Importance: For critically ill adults undergoing emergency tracheal intubation, failure to intubate the trachea on the first attempt occurs in up to 20% of cases and is associated with severe hypoxemia and cardiac arrest. Whether using a tracheal tube introducer ("bougie") increases the likelihood of successful intubation compared with using an endotracheal tube with stylet remains uncertain.

Objective: To determine the effect of use of a bougie vs an endotracheal tube with stylet on successful intubation on the first attempt.

Design, Setting, and Participants: The Bougie or Stylet in Patients Undergoing Intubation Emergently (BOUGIE) trial was a multicenter, randomized clinical trial among 1102 critically ill adults undergoing tracheal intubation in 7 emergency departments and 8 intensive care units in the US between April 29, 2019, and February 14, 2021; the date of final follow-up was March 14, 2021.

Interventions: Patients were randomly assigned to use of a bougie (n = 556) or use of an endotracheal tube with stylet (n = 546).

Main Outcomes and Measures: The primary outcome was successful intubation on the first attempt. The secondary outcome was the incidence of severe hypoxemia, defined as a peripheral oxygen saturation less than 80%.

Results: Among 1106 patients randomized, 1102 (99.6%) completed the trial and were included in the primary analysis (median age, 58 years; 41.0% women). Successful intubation on the first attempt occurred in 447 patients (80.4%) in the bougie group and 453 patients (83.0%) in the stylet group (absolute risk difference, -2.6 percentage points [95% CI, -7.3 to 2.2]; P = .27). A total of 58 patients (11.0%) in the bougie group experienced severe hypoxemia, compared with 46 patients (8.8%) in the stylet group (absolute risk difference, 2.2 percentage points [95% CI, -1.6 to 6.0]). Esophageal intubation occurred in 4 patients (0.7%) in the bougie group and 5 patients (0.9%) in the stylet group, pneumothorax was present after intubation in 14 patients (2.5%) in the bougie group and 15 patients (2.7%) in the stylet group, and injury to oral, glottic, or thoracic structures occurred in 0 patients in the bougie group and 3 patients (0.5%) in the stylet group.

Conclusions and Relevance: Among critically ill adults undergoing tracheal intubation, use of a bougie did not significantly increase the incidence of successful intubation on the first attempt compared with use of an endotracheal tube with stylet.

Trial Registration: ClinicalTrials.gov Identifier: NCT03928925.

Clinical Institute

Cancer

Department

Emergency Medicine

Department

Oncology

Share

COinS